Factors Affecting Power: Significance Level (2 of 2)
Next section: Sample size
The power for the three values of μ
diff
at the two significance levels is shown below.
μdiff |
0.05 |
0.01 |
10
20
30 |
0.17
0.52
0.85 |
0.07
0.28
0.66 |
It stands to reason that the power would be higher for the 0.05
level than for the 0.01 level. The cost of stronger protection against
Type I errors is more
Type II errors.